Skip to main content

TACTILE COLD SCISSOR METROPLASTY AS A NOVEL BACKUP METHOD FOR HYSTEROSCOPIC METROPLASTY

مؤلف البحث
Ali M. El Saman; Atef M. Darwish; Mahmoud S. Zakherah; Hossam O. Hamed; Mohamed A. Bedaiwy; Ahmed M. Nasr
مجلة البحث
Fertility and Sterility
المشارك في البحث
الناشر
NULL
تصنيف البحث
1
عدد البحث
2009 Jul
موقع البحث
NULL
سنة البحث
2009
صفحات البحث
NULL
ملخص البحث

Objective: To study the operative, anatomic and functional
outcome of tactile cold scissor metroplasty (TCSM) as a backup method for hysteroscopic metroplasty.
Design: Case series with description of the technique.
Setting: Assiut University Women’s Health Center.
Patient(s): Three cases with failed hysteroscopic metroplasty out of 127 cases with uterine septa scheduled for hysteroscopic resection.
Intervention(s): The TCSM procedure was performed in three cases under direct laparoscopic monitoring.
Main Outcome Measure(s): Operative time, complications,
hysteroscopic appearance of the cavity, reproductive outcome,
and reintervention rates.
Results: The TCSM procedure was performed successfully in the three cases with a short total operative time (10-12 minutes). Subsequent office hysteroscopic appearance was satisfactory. Patients were then followed-up for a period of time ranging from 3 to 28 months. One case had a successful pregnancy outcome, one has an ongoing pregnancy, and the last one did not get pregnant so far.
Conclusion(s): Tactile cold scissor metroplasty is a useful, safe, and effective backup procedure for hysteroscopic metroplasty.