Skip to main content

Entropy Generation in Counter Flow Gas to Gas Heat Exchangers

مؤلف البحث
Hany. A. M. Beblawy
المشارك في البحث
سنة البحث
2006
مجلة البحث
Journal of Heat Transfer, ASME
عدد البحث
Vol. 128, No. 1
تصنيف البحث
1
صفحات البحث
PP. 87-92
ملخص البحث

Analysis of heat transfer and fluid flow thermodynamic irreversibilities is realized on an example of a counter flow double pipe heat exchanger utilizing turbulent air flow as a working fluid. During the process of mathematical model creation and for different working and constructing limitations, total thermodynamic irreversibility is studied.
The present work proves that the irreversibility is occurred due to unequal capacity flow rates (flow imbalance irreversibility). It is concluded that the heat exchanger should be operated at effectiveness greater than 0.5 and the best design will be achieved when  approach from one where low irreversibility is expected.
A new equation is adopted to express the entropy generation numbers for imbalanced heat exchangers of similar design with smallest deviation from the exact value. The results obtained from the new equation are compared with the exact values and with that obtained by another author