STUDY OF THE EFFECTS OF USING ACETIC ACID IN CONDENSER DE-SCALING ON THE EXHAUST EMISSIONS AND THE PERFORMANCE OF ASSIUT THERMAL POWER PLANT

مؤلف البحث
M. F. Bady, H. M. Hassanien, S. A. S. Mousa, A. M Hussein, A. M. K. El-Dean
المشارك في البحث
سنة البحث
2013
مجلة البحث
Journal of Engineering Sciences, Assiut University, Faculty of Engineering
عدد البحث
41- 3
تصنيف البحث
2
صفحات البحث
971 - 996
ملخص البحث

In the present study, an investigation of the effect of using acetic acid (CH3COOH) in condenser de scaling on the exhaust emissions and the performance of Assiut Thermal Power Plant. Efficient
condenser operation maintains turbine efficiency; benefits consumers by reducing the amount of
emissions. Condenser vacuum has a great effect on the unit efficiency to a degree that it reduces the
generated load by 112 MW (35.9%) in unit one of Assiut Power Plant and to the extent that cleaning
became very necessary. From environmentally point of view an organic, biodegradable, locally
produced, effective and cheap de-scaling agent was the very applicable one and this meet with acetic
acid. Actually, condenser cleaning leads to an improvement in the turbine efficiency and raises the
maximum load generated from the unit (from 200 MW before cleaning to 290 MW after cleaning),
decreases fuel consumed for MW (from 249 kg/MWh at load 200 MW to 220 kg/MWh at load 290
MW), reduces the overall fuel consumption, consequently, reduces emissions as CO, CO2, SOx,
NOx, ground level ozone, PM, VOC, ashes, solid deposits, haze, thermal pollution, and reduces
contribution to global warming, heat island effect at Assiut city. In brief, the condenser cleaning
process reduces the environmental pollution from the unit which in turn minimizes the health impact
of these pollutants.