Skip to main content

Simultaneous determination of tramadol, O-desmethyltramadol and
N-desmethyltramadol in human urine by gas chromatography–mass
spectrometry

Research Authors
Abdel-Aziz Y. El-Sayed, Khaled M. Mohamed, Ahmed Y. Nasser, Jennifer Button,
David W. Holt
Research Department
Research Journal
Journal of Chromatography
Research Member
Research Rank
1
Research Year
2013
Research_Pages
PP.9– 15
Research Abstract

Analytical procedures for the determination of tramadol (T), O-desmethyltramadol (ODT), and
N-desmethyltramadol (NDT) in human urine have been developed and validated using gas
chromatography–mass spectrometry (GC/MS). Sample preparation involved liquid–liquid extraction
with methyl-tert-butyl ether (MTBE) and followed by back extraction with 0.1 M hydrochloric acid.
Proadifen (SKF525A) was selected as internal standard (IS). Extraction efficiencies of T, ODT and NDT were
102.12, 101.30, and 98.21%, respectively. The calibration curves were linear (r2 > 0.99) in the concentration
range 10–1000 ng/mL for all compounds. Limits of quantification (LOQ) were 10, 10 and 20 ng/mL for
T, ODT and NDT, respectively. Intra-assay precision was within 1.29–6.48% and inter-assay precision was
within 1.28–6.84% for T, ODT and NDT. Intra-assay accuracy was within 91.79–106.89% for all analytes.
This method detected urine concentrations of T, ODT and NDT in six healthy volunteers for 7 days after
administration of 50 mg oral doses of tramadol.