Skip to main content

Poly (bromocresol green) Flakes-Decorated Pencil Graphite Electrode for Selective Electrochemical Sensing Applications and Pharmacokinetic Studies

مؤلف البحث
Mohamed I. Gadallah, Hassan Refat H. Ali, Hassan F. Askal, Gamal A. Saleh
مجلة البحث
Materials Science & Engineering C
الناشر
NULL
تصنيف البحث
1
عدد البحث
Vol. 102
موقع البحث
https://doi.org/10.1016/j.msec.2019.03.071
سنة البحث
2019
المشارك في البحث
ملخص البحث

A square wave voltammetric method for selective determination of meropenem (MRP) and ertapenem (ERP) was developed using pencil graphite electrode modified with poly (bromocresol green) (PGE/PBCG). The modified electrode film was characterized by scanning electron microscopy and electro-chemical impedance spectroscopy. Under the optimized conditions, the prepared electrode has good linearity over concentration range 1.0–60.0 and 0.3.0–75.0 μM for MRP and ERP, respectively. The developed method was validated according to ICH guidelines. In addition, the diffusion co-efficients of MRP and ERP were estimated to be 1.24×10−6 and 9.09×10−6 cm2 s−1, respectively using chronoamperometric technique. The developed method was highly sensitive and selective for the determination of MRP or ERP in the presence of their corresponding open beta-lactam ring degradation products. Consequently, it was successfully utilized for in-vitro and in-vivo applications in spiked and real plasma samples of healthy rabbits for their pharmacokinetic studies. Furthermore, the method was applied for the assay of the available dosage forms of both drugs.